September 7, 2010
Estimated Performance Guidelines
The following performance guidelines are based on test conditions outlined under
"A/C System Operational Check for Evans Midway and High Performance Systems"
. Variables such as engine speed, condenser airflow, sun load, blower motor speed, and chassis voltage will all affect A/C system performance.
Air Temperature (F) Entering A/C Unit
Inlet - Outlet Air Temperature Differential**
FRESH OR RECIRCULATED
LOW HUMIDITY
HIGH HUMIDITY
50
5-10
5-10
60
10-20
10-15
70
20-25
15-20
80
25-30
20-25
90
25-35
20-30
100
30-35
25-30
110
35-40
30-35
** The outlet louver closest to the A/C unit usually discharges the coldest air. The warmest inlet air temperature (fresh or recirculated) should also be used for the Differential calculation.
A/C System Operating Pressures
Ambient Air Temp (F) Entering Condenser
Suction Pressure (PSIG) @ Evaporator Outlet
Discharge Pressure (PSIG) @ Compressor Outlet
50
5-15
75-125
60
5-15
100-150
70
10-20
125-175
80
10-20
150-225
90
15-25
175-250
100
15-25
200-275
110
15-30
225-325
Go Back to Technical Support